Features

  1. 20 User Codes
  2. Auto-unlock after set period
  3. Auto-unlock at set time
  4. Dual Authorisation

Operating


Finishes
Brushed Steel
IP Rating
Refer to fitting instructions. Gasket required.
IP55
Key Override
Yes
Lock Type
Cam*
Operations
100,000
Orientations
Vertical
Temperature Range
0°C - 55°C

Power


Batteries
2x AAA
Battery Override
Yes

*Slam latch accessory available separately. The slam latch is fitted in-lieu of the cam.

Management

Master Code
Management and administration of the lock. In Public Function, the Master Code will also clear an active User Code. The Master Code is 8 digits in length.

Sub-Master Code
Basic administration of the lock. The Sub-Master Code is 8 digits in length.

Technician Code
In Public Function, the Technician Code will open a lock but not clear an active User Code. The lock will automatically re-lock. The Technician Code is 6 digits in length.

Standard Features

Re-Lock Delay

The number of seconds before the lock will re-lock in any Private Function.

Restrict Operating Time

Control the hours during which the lock will

Private Function

Once set, the User Code allows repeated unlocking of the lock. The lock will always re-lock automatically. This function is used for long term usage where a locker is typically allocated to an individual.

User Codes

A default User Code of 2244 is set in Private Function. Up to 20 User Codes can be added. User Codes are 4 digits in  length.

Dual Authorisation

Any two valid User Codes must be entered for access.

Public Function

The user enters their own personal four-digit code to lock the lock. Entering the same code will open the lock and clear the code, ready for the next user. This function is used for short term, multi occupancy applications, e.g. a  locker in a leisure centre. User Codes are 4 digits in length.

Single Entry

Single entry of the chosen User Code will lock the lock.

Double Entry

The chosen User Code must be repeated for locking.

Set a Maximum Locked Period

When set, the lock, if locked, will unlock automatically after a set number of hours.

Auto-unlock at a set time

When set, the lock, if locked, will unlock automatically at a set time.

Programming

Master User

The Master User is effectively the administrator of the lock. All programs are available to the Master User. The Master Code should be changed before active use.

Change Master Code

#Master Code 01  New Master Code  New Master Code  ••
Example : #11335577  •  01   •  12345678   •  12345678  ••
Result : Master Code has been changed to 12345678

Standard User

A standard user can use the lock within the configuration applied

Set or Change a User Code

#(Sub)Master Code   •  02  •  User Position   •  User Code  ••
Example : #11335577   •  02   •  01   •  1234  ••
Result : The User Code 1234 has been added to position 01
Note : A user can change their own code using the program below:
#User Code  •  New User Code  •  New User Code  ••
Example : #1234  •  9876  •  9876  ••
Result : The user's code has now been set to 9876.

Delete a User Code

#(Sub)Master Code  •  03   •  User Position  ••
Example : #11335577  •  03   •  06  ••
Result : The User Code in position 06 has been deleted
Note :   Entering 00 as position will delete all User Codes

Sub-Master User

The Sub-Master has access to the majority of the programs but cannot change or delete the Master User. The Sub-Master User is not required for operation.

Set or Change Sub-Master Code

#(Sub)Master Code  •  04  •  New Sub-Master Code   •  Confirm New Sub-Master Code  ••
Example : #11335577  •  04  •  99775533   •  99775533  ••
Result : The Sub-Master Code 99775533 has been added

Delete the Sub-Master Code

#Master Code  •  05  •  05  ••
Example : #11335577  •  05  •  05  ••
Result : The Sub-Master Code has been deleted

Technician User

The technician can open a lock. After opening, the lock will automatically re-lock after four seconds. In public function, the active user code will remain valid. In private function, the technician is essentially an  additional standard user.

Set or Change Technician Code

#(Sub)Master Code  •  13  •  New Technician Code  •  Confirm New Technician Code  ••
Example : #11335577  •  13  •  555777  •  555777  ••
Result : The Technician Code 555777 has been added

Delete Technician Code

#(Sub)Master Code   •  13   •  000000   •  000000  ••
Example : #11335577  13  000000   000000  ••
Result : The Technician Code has been deleted

Operating Functions

Public Use - Double Entry

The default state of the lock is unlocked. To lock, the user must enter a 4 digit code of their choice and repeat for confirmation. After locking, on re-entering their code, the lock will unlock and remain unlocked  ready for the next user.
Note : Entering the Master or Sub-Master code when the lock is in Public Function will clear the active user code and put the lock into an unlocked state ready for a new user.
#Master Code  22  ••
Example : #11335577   22  ••
Result:  The lock will remain open until the next user enters a 4 digit code. The user will be required  to confirm their code (double entry).
Note : On re-entry of the same 4-digit code, the lock will open.

Public Use - Single Entry

The default state of the lock is unlocked. To lock, the user must enter a 4 digit code of their choice. The user does not need to confirm their code. After locking, on re-entering their code, the lock will unlock and  remain unlocked ready for the next user.
#Master Code  •  24  ••
Example : #11335577  24  ••
Result : The lock will remain open until the next user enters a 4 digit code. The user will not be  required to confirm their code. Once entered, the lock will lock.
Note : On re-entry of the same 4-digit code, the lock will open.

Private Use

The default state of the lock is locked. A single default user is registered with a code of 2244. A total of 20 user codes can be added to the lock. Entering a valid user code will unlock the lock. The lock will  automatically re-lock after four seconds.
#Master Code  26  ••
Example : #11335577  26  ••
Result : The lock will remain locked until a User, Technician, Sub-Master or Master Code is entered.

Configuration

Change Sounder State

Enable
Example : #11335577  • 07  •  01  ••
Result : Enables sounder.

Disable
Example : #11335577  • 07  •  00  ••
Result : Disables sounder.

Locked LED Indication

When enabled (default), the red LED will flash every 5 seconds to indicate locked status.
#Master Code   08  •  Enable/Disable <00|01>  ••

Enable
Example : #11335577  08   01  ••
Result : Enables locked LED indication.

Disable
Example : #11335577  08   00  ••
Result : Disables locked LED indication.


Dual Authorisation

Requires any two active User Codes to be entered within 5 seconds for the lock to unlock.
#Master Code   09   Enable/Disable <00|01> 

Enable
Example : #11335577   09   01 
Result : Dual authorisation has been enabled. Any two active User Codes must be entered to unlock.

Disable
Example : #11335577   09   00 
Result : Dual authorisation has been disabled.

Auto-Unlock after X Hours

Unlocks the lock automatically after a pre-determined time of being locked.
#Master Code    10  Time <01-24>  ••
Example : #11335577   10  06  ••
Result : The lock will unlock 6 hours after locking.

Disable
#Master Code  10  00  ••

Auto-Unlock at a Set Time

Unlocks the lock automatically at specific time. Requires date & time to be set (Program 12).
#Master Code   11   HHmm 
Example : #11335577   11   2000 
Result : The lock will unlock at 20:00.

Disable
#Master Code   11  •  2400 

Set or Change Date & Time

Date/time is required for auto-open at a set-time functions.
#(Sub)Master Code  12   YYMMDD   HHmm 
Example : #11335577   12   200226   1128  ••
Result : The date/time has been set to February 26th, 2020 11:28.
Note : DST is not supported.

Restrict Operating Time

Restricts locking within the set hours. In Private Function, no locking or unlocking will be possible. In Public Function, no locking will be possible. Master and Sub-Master will always allow access.  All Master and  Sub-Master programs remain available.
#Master Code   18   HHmm (Start)   HHmm (End) 
Example : #11335577   18   0830   1730 
Result : User Code can only be used between 08:30 and 17:30.

Other Functions

Battery Level Check

#Master Code  87  ••
Example : #11335577  87  ••

<20%
20-50%
50-80%
>80%

•  
•   •  
•   •   •  

Factory Reset

Via Keypad

#Master Code   99   99 
Example: #11335577   99   99 
Result: The motor will engage and both LEDs will flash to indicate the lock has reverted to factory
settings.

Via Power Reset

1. Disconnect power
2. Press & hold 1 button
3. Reconnect power whilst holding down 1 button
4. Release 1 button & within three seconds, press 1 three times


    • Related Articles

    • CL4500 - Programming and Operating Instructions

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. About CL4500 The CL4500 and ...
    • CL5500 - Programming and Operating Instructions

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support . About CL5500 The CL4500 and ...
    • KL1100 RFID - Programming and Operating Instructions

      ABOUT KL1100 RFID The KL1100 RFID can operate in Standalone Mode or in Remote Card Authorisation (RCA) Mode. RCA Mode gives the ability to remotely set-up and allocate cards to locks or lock groups  with our offline or cloud based software. ...
    • Codelocks US Website Terms and Conditions

      BUYER CONSENTS TO THE FOLLOWING TERMS AND CONDITIONS: Seller’s acceptance of Buyer’s orders is expressly made conditional on Buyer’s assent to these terms and conditions.   Introduction This website is owned and operated by Codelocks. Any orders ...
    • NANO90 - Programming & Operating Instructions

      The Nano 90 was discontinued on January 6th, 2022. Codes - The Basics The KitLock Nano90 has four code levels available: i) Master Code ii) Sub-Master Code iii) User Code iv) Technician Code The NANO90 is supplied with two factory set codes: Master ...