Before programming select the most appropriate function for the application.
A) Private Use
Important Note: This is the default function and is already pre-programmed in new locks.
This is the most common function and is used where the same code will be repeatedly used.
B) Public Use
The user enters their own personal four-digit code. This locks the lock. The same code is entered to open the lock before being erased and ready for the next new user.
This function is used for short-term, multi occupancy applications, e.g. hot desking in an office or a locker in a leisure centre.
The NANO90 has a 10 button keypad, * and # button. The * and # buttons are only used for programming functions.
The NANO90 KitLock has the following code levels:
Master Code
The Master Code can:
Sub-Master Code
The Sub-Master Code can:
• Blue LED = Code accepted
• Red LED = Code rejected
User Code
The User Code can:
Technican Code
The Technician Code can:
The same code cannot be programmed into more than one level.
Lost Master Code Procedure
Note: The procedure requires the door to be open.
Penalty TIme
Battery Power
The KitLock should provide well in excess of 100,000 openings, of 4 seconds each, from 1 x coin cell.
Low Battery
The lock will operate for 100 times with low battery.
Battery Override
The NANO90 has been designed so a PP3 battery can be placed against the external contacts so that the lock can be opened to replace the battery should it fail.
The procedure is as follows:
Change the Master Code
#Master Code • 01 • New Master Code • New Master Code ••
Example: #11335577 • 01 • 12345678 • 12345678 ••
Result: Master Code has been changed to 12345678.
Set or Change the User Code
#Master Code • 02 • User Code ••
Example: #11335577 • 02 • 9999 ••
Result: New User Code 9999 now operative.
Delete the User Code
#Master Code • 03 ••
Example: #11335577 • 03••
Result: User Code deleted.
Set or Change the Sub-Master Code
#Master Code • 04 • Sub-Master Code • Sub-Master Code ••
Example: #11335577 • 04 • 87654321 • 87654321 ••
Result: Sub-Master Code 87654321 now operative.
Delete the Sub-Master Code
#Master Code • 05 • 05 ••
Example: #11335577 • 05 • 05 ••
Result: Sub-Master Code deleted.
Change the Sub-Master Code
#Sub-Master Code • 06 • New Sub-Master Code • New Sub-Master Code ••
Example: #87654321 • 06 • 10101010 • 10101010 ••
Result: Sub-Master Code has been changed to 10101010.
Set or Change the User Code
#Sub-Master Code • 07 • User Code ••
Example: #87654321 • 07 • 6666 ••
Result: New User Code 6666 now operative.
Delete the User Code
#Sub-Master Code • 08 ••
Example: #87654321 • 08 ••
Result: User Code deleted.
Change the User Code
#User Code • New User Code • New User Code ••
Example: #2244 • 6688 • 6688 ••
Result: User Code now 6688.
Public Use
#Master Code • 09 ••
Example: #11335577 • 09 ••
Result: The lock will now remain open until the next user enters their own personal code into the lock as follows:
Step 1 - Enter 4 digit code close the locker which will now be locked.
Step 2 - Enter the same 4 digit code the lock will now open and remain open until next 4 digit code is entered.
Note: The Master Code and Sub-Master Code will be retained from A - Private Use.
Restrict the Locked Time
#Master Code • 10 • (number of hours lock to remain locked) ••
Example: #11335577 • 10 • 04 ••
Result: The lock will auto open after 4 hours. If a new User Code is entered it will relock for 4 hours. If the lock is opened during the 4 hour period then the lock remains open until a new User Code is entered.
Note: This program only works when the lock is set in B - Public Use Function. The lock can be set to remain locked for 02, 04, 06, 08, 10 or 12 hours.
Private Use
#Master Code • 11 ••
Example: #11335577 • 11 ••
Result: The lock will revert back to default function A - Private Use Function. Factory set User Code 2244 will now work repeatedly until reprogrammed.
Set Technical Code
#Master Code • 12 • Technician Code • Technician Code ••
Example: #11335577 • 12 • 555555 • 555555 ••
Result: The lock is automatically set into B - Public Use Function and allows the programmed Technician Code to open the lock WITHOUT the entered User Code being erased.
Note: If lock is opened with a Master Code the User Code will be erased.
Delete the Technician Code
#Master Code • 13 • 13 ••
Example: #11335577 • 13 • 13 ••
Result: Technician Code deleted.
POI-KL90-v2:0716