KL1000 Classic Programming and Operating Instructions [GB]

KL1000 Classic Programming and Operating Instructions [GB]

CODES - THE BASICS
The KitLock has four code levels available:
  1. Master Code
  2. Sub-Master Code
  3. User Code
  4. Technician Code
The KitLock is supplied with two factory set codes:
Master Code: 11335577
User Code: 2244
  1. When fitted, immediately change the Master Code and User Code.
  2. All Master Codes and Sub-Master codes are 8 digits long.
  3. All User Codes are 4 digits long.
  4. All Technician Codes are 6 digits long.
  5. The lock ‘open’ time is set at 4 seconds.

FUNCTIONS
Before programming, select the most appropriate function for the application
A) PRIVATE USE
Important Note: This is the default function and is already pre-programmed in new locks. This is the most common function and is used where the same code will be repeated used.
B) PUBLIC USE
The user enters their own personal 4 digit code. This locks the lock. The same code is entered once only to open the lock before being erased and ready for the next new user. This function is used for short term, multi occupancy applications, e.g. a locker in a leisure centre.

OPERATING INSTRUCTIONS
Note: The KitLock has a 10 button keypad and a # button. The # button is hidden beneath the handle when in the locked position.

CODES - The lock has the following code levels:

MASTER CODE
The Master Code can:
  1. Open the lock
  2. Change the Master Code
  3. Set / Change / Delete the Sub-Master and User Code
  4. Select between Private and Public Functions
  5. Activate / Deactivate Technician Code
SUB-MASTER CODE
The Sub-Master Code can:
  1. Open the lock
  2. Change the Sub-Master Code
  3. Set / Change / Delete the User Code
USER CODE
The User Code can:
  1. Open the lock
  2. Change the User Code
TECHNICIAN CODE
The Technician Code can:
  1. Open the lock
A code cannot be programmed into more than one level.

LOST CODE PROCEDURE
Note: The procedure requires the door to be open.
  1. Remove the rear-fixing bolt and swing the lock over the edge of the door to reveal the battery compartment.
  2. Remove one battery.
  3. Press and hold the 1 button, replace the battery, the Blue LED will flash twice, release the 1 button. Within three seconds press the 1 button three times. The Blue LED will flash twice and the lock will have reverted to the factory Master Code 11335577 and all other stored settings will be erased.
PENALTY TIME
  1. Entering three incorrect codes will cause the lock to shutdown for 10 seconds.
BATTERY POWER
  1. The KitLock should provide well in excess of 15,000 openings, of 4 seconds each, from 2 x AAA 1.5v cells.
LOW BATTERY
  1. When the battery power is low the Red LED will flash 3 times before the Blue LED lights, accepting the code. Fit new batteries as soon as this happens. The lock will operate for 100 times with low battery.
BATTERY FAILURE OVERRIDE
The KitLock has been designed so an external PP3 battery can be placed against the contact points surrounding the Blue and Red LED’s so the lock can be opened to replace the batteries should they fail.
The procedure is as follows:
  1. Place the contact points of the PP3 battery against the contact points surrounding the Blue and Red LED’s.
  2. The positive + PP3 terminal against the Red LED and the negative - PP3 terminal against the Blue LED.
  3. Enter the Master Code.
  4. The motor will withdraw the locking pin allowing the lock to be opened.
  5. Fit new batteries by removing the upper fixing bolt and swinging the lock down over the edge of the door. Refit the lock.

PROGRAMMING
To program - the lock must be in the open position with the # button visible. Every program command must commence by pressing the # button, followed by other the Master Code, Sub-Master Code or User Code.

MASTER CODE COMMANDS
CHANGE THE MASTER CODE
#Master Code  01  New Master Code  New Master Code 
Example: #11335577  01  12345678  12345678 
Result: Master Code has been changed to 12345678.

SET OR CHANGE THE USER CODE
#Master Code  02  User Code 
Example: #11335577  02  9999 
Result: New User Code 9999 now operative.

DELETE THE USER CODE
#Master Code  03 
Example: #11335577  03 
Result: User Code deleted.

SET OR CHANGE THE SUB-MASTER CODE
#Master Code  04  Sub-Master Code  Sub-Master Code 
Example: #11335577  04  87654321  87654321 
Result: Sub-Master Code 87654321 now operative.

DELETE THE SUB-MASTER CODE
#Master Code  05  05 
Example: #11335577  05  05 
Result: Sub-Master Code deleted.

BATTERY LEVEL CHECK
#Master Code  09 
Example: #11335577  09 
Result: Both  Red LED and  Blue LED will flash to indicate current battery status:
• • •  More than 80% charged
• • • Between 50%-80% charged
• • Between 20-50% charged
• Less than 20% charged



SUB-MASTER CODE COMMANDS
CHANGE THE SUB-MASTER CODE
#Sub-Master Code  06  New Sub-Master Code  New Sub-Master Code 
Example: #87654321  06  10101010  10101010 
Result: Sub-Master Code has been changed to 10101010.

SET OR CHANGE THE USER CODE
#Sub-Master Code  07  User Code 
Example: #87654321  07  6666 
Result: New User Code 6666 now operative.

DELETE THE USER CODE
#Sub-Master Code  08 
Example: #87654321  08 
Result: User Code deleted.

USER CODE COMMANDS
CHANGE THE USER CODE
#User Code  New User Code  New User Code 
Example: #2244  6688  6688 
Result: New User Code 6688 now operative.

SPECIAL MASTER CODE COMMANDS
SET A) PRIVATE USE
#Master Code  26 
Example: #11335577  26 
Result: The lock will revert back to default A) Private Use Function. Factory set User Code 2244 will now work repeatedly until reprogrammed.

SET B) PUBLIC USE - SINGLE CODE ENTRY (DEFAULT)
#Master Code  24 
Example: #11335577  24 
Result: The lock will now remain open until the next user enters their own personal code into the lock as follows:
Step 1 - Enter 4 digit code  Close the locker which will now be locked.
Step 2 - Enter the same 4 digit code  The lock will now open and remain open until next 4 digit code is entered.

SET B) PUBLIC USE - DOUBLE CODE ENTRY
#Master Code  22 
Example: #11335577  22 
Result: The lock will now remain open until the next user enters their own personal code into the lock as follows:
Step 1 - Enter 4 digit code  Repeat 4 digit code  Close the locker which will now be locked.
Step 2 - Enter the same 4 digit code  The lock will now open and remain open until next 4 digit code is entered as Step 1.
Note: When locked in this mode the  Red LED will flash every 5 seconds to indicate the locker is locked.

SET TECHNICIAN CODE
#Master Code  99  Technician Code  Technician Code 
Example: #11335577  99  555555  555555 
Result: The lock is automatically set into B) Public Use Function and allows the programmed Technician Code to open the lock WITHOUT the entered single User Code being erased.
Note: If the lock is opened with a Master Code the User Code will be erased.

POI_KL1000EU_v1:1017


    • Related Articles

    • KL1000 Classic Getting Started Guide [GB]

      The KL1000 Classic is supplied with a factory set Master Code (11335577) and User Code (2244), and the Private Use Function enabled.  In this function, the lock will remain locked until a valid 4 digit User Code is entered. On entry of a valid User ...
    • KL1000 G3 Programming and Operating Instructions [GB]

      The KL1000 G3 is the third generation KL1000 series cabinet lock introducing key-override, on-door battery change and updated finishes. Sharing the same fittings & fixings as the KL1000 Classic, this lock is ideal for upgrading older installations ...
    • KL1000 Classic+ - Programming and Operating Instructions

      IMPORTANT: This guide is for the KL1000 Classic+ model. The standard KL1000 Classic Programming and Operating Instructions are available here. The KL1000 Classic+ is a compact digital lock based on the venerable KL1000 Classic, with the additional ...
    • KL1100 RFID - Programming and Operating Instructions

      ABOUT KL1100 RFID The KL1100 RFID can operate in Standalone Mode or in Remote Card Authorisation (RCA) Mode. RCA Mode gives the ability to remotely set-up and allocate cards to locks or lock groups  with our offline or cloud based software. ...
    • KL1000 Classic - 2013 Vertical Programming & Operating Instructions

      Codes - The Basics The KitLock has four code levels available: Master Code Sub-Master Code User Code Technician Code The KitLock is supplied with two factory set codes: Master Code: 11 33 55 77 User Code: 22 44 When fitted immediately change the ...