KL1000 Classic - 2015 Programming and Operating Instructions

KL1000 Classic - 2015 Programming and Operating Instructions

Codes - The Basics

The KitLock has four code levels available:

  1. Master Code

  2. Sub-Master Code

  3. User Code

  4. Technician Code

 

 

The KitLock is supplied with two factory set codes:

  1. Master Code: 11335577

  2. User Code: 2244

  • When fitted, immediately change the Master Code and User Code.

  • All Master Codes and Sub-Master Codes are 8 digits long.

  • All User Codes are 4 digits long.

  • All Technician Codes are 6 digits long.

  • The lock ‘open’ time is set at 4 seconds.

 

Functions

Before programming, select the most appropriate function for the application:
A) or B) – See special Master Code set up commands.


A) PRIVATE USE
Important Note: This is the default function and is already pre-programmed in new locks. This is the most common function and is used where the same code will be repeatedly used.


B) PUBLIC USE
The user enters their own personal four-digit code. This locks the lock. The same code is entered once only to open the lock before being erased and ready for the next new user. This function is used for short term, multi occupancy applications, e.g. a locker in a leisure centre.

 

Operating Instructions

Note: The KitLock has a 10 button keypad and a # button. The # button is hidden beneath the handle when in the locked position.

CODES The lock has the following code levels:


MASTER CODE
The Master Code can:

  • Open the lock

  • Change the Master Code

  • Set / Change / Delete the Sub-Master and User Code

  • Select between Private and Public Functions

  • Activate/deactivate Technician Code

SUB-MASTER CODE
The Sub-Master Code can:

  • Open the lock

  • Change the Sub-Master

  • Set / Change / Delete / the User Code

USER CODE
The User Code can:

  • Open the lock

  • Change the User Code

• Blue LED = Code accepted
Red LED = Code rejected

TECHNICIAN CODE
The Technician Code can:

  • Open the lock
    A code cannot be programmed into more than one level.

LOST CODE PROCEDURE
Note: The procedure requires the door to be open

  • Remove the rear-fixing bolt and swing the lock over the edge of the door to reveal the battery compartment.

  • Remove one battery.

  • Press and hold the 1 button, replace the battery, the Blue LED will flash twice, release the 1 button. Within three seconds press the 1 button three times. The Blue LED will flash twice and the lock will have reverted to the factory Master Code 11335577 and all other stored settings will be erased.

PENALTY TIME

  • Entering three incorrect codes will cause the lock to shutdown for 10 seconds.

BATTERY POWER

  • The KitLock should provide well in excess of 15,000 openings, of 4 seconds each, from 2 x AAA 1.5v cells.


LOW BATTERY

  • When the battery power is low the  Red LED will flash 3 times before the  Blue LED lights, accepting the code. Fit new batteries as soon as this happens. The lock will operate for 100 times with low battery.

 

 

BATTERY FAILURE OVERRIDE

The KitLock has been designed so an external PP3 battery can be placed against the contact points surrounding the Blue and Red LED’s so the lock can be opened to replace the batteries should they fail.
The procedure is as follows:

  • Place the contact points of the PP3 battery against the contact points surrounding the Blue and Red LED’s.

  • The positive + PP3 terminal against the Red LED contact point and the negative – PP3 terminal against the Blue LED.

  • Enter the Master Code.

  • The motor will withdraw the locking pin allowing the lock to be opened.

  • Fit new batteries by removing the upper fixing bolt and swinging the lock down over the edge of the door. Refit the lock.

 

 

 

Programming

To program – the lock must be in the open position with the # button visible. Every program command must commence by pressing the # button, followed by either the Master Code, Sub-Master Code or User Code.

 

MASTER CODE COMMANDS

 

CHANGE THE MASTER CODE
#Master Code  01  New Master Code  New Master Code ••
Example: #11335577  01  12345678  12345678 ••
Result: Master Code has been changed to 12345678.

 

SET OR CHANGE THE USER CODE
#Master Code  02  User Code ••
Example: #11335577  02  9999 ••
Result: New User Code 9999 now operative.

 

DELETE USER CODE
#Master Code  03 ••
Example: #11335577  03 ••
Result: User Code deleted.

 

SET OR CHANGE THE SUB-MASTER CODE
#Master Code  04  Sub-Master Code  Sub-Master Code ••
Example: #11335577  04  87654321  87654321 ••
Result: Sub-Master Code 87654321 now operative.

 

DELETE THE SUB-MASTER CODE
#Master Code  05  05 ••
Example: #11335577  05  05 ••
Result: Sub-Master Code deleted.

 

SUB-MASTER CODE COMMANDS

 

CHANGE THE SUB-MASTER CODE
#Sub-Master Code  06  New Sub-Master Code  New Sub-Master Code ••
Example: #87654321  06  10101010  10101010 ••
Result: Sub-Master Code has been changed to 10101010.

SET OR CHANGE THE USER CODE
#Sub-Master Code  07 • User Code ••
Example: #87654321  07  6666 ••
Result: New User Code 6666 now operative.

DELETE USER CODE
#Sub-Master Code  08 ••
Example: #87654321  08 ••
Result: User Code deleted.

 

USER COMMAND

 

CHANGE THE USER CODE
#User Code  New User Code  New User Code ••
Example: #2244  6688  6688 ••
Result: User Code now 6688.

 

BATTERY LEVEL CHECK
#
Master Code  09 ••
Example: #11335577  09 ••
Result: Both  Red LED and  Blue LED will flash to indicate current battery status.

More than 80% charged                     
Between 50%-80% charge            
Between 20%-50% charged      
Less than 20% charged        

 

SPECIAL MASTER CODE COMMANDS

 

SET A) PRIVATE USE
#Master Code  26 ••
Example: #11335577  26 ••
Result: The lock will revert back to default A) Private Use Function.
Factory set User Code 2244 will now work repeatedly until reprogrammed.

 

SET B) PUBLIC USE – SINGLE CODE ENTRY (DEFAULT)
#Master Code  24 ••
Example: #11335577  24 ••
Result: The lock will now remain open until the next user enters their own personal code into the lock as follows:
Step 1 – Enter 4 digit code  Close the locker which will now be locked.
Step 2 – Enter the same 4 digit code •• the lock will now open and remain open until next 4 digit code is entered.


SET B) PUBLIC USE – DOUBLE CODE ENTRY
#Master Code  22 ••
Example: #11335577  22 ••
Result: The lock will now remain open until the next user enters their own personal code into the lock as follows:
Step 1 – Enter 4 digit code  Repeat 4 digit code ••
Close the locker which will now be locked.
Step 2 – Enter the same 4 digit code •• the lock will now open and remain open until next 4 digit code is entered as Step 1.
Note: When locked in this mode  LED will flash every 5 seconds to indicate the locker is locked.

 

SET TECHNICIAN CODE
#Master Code  99  Technician Code  Technician Code ••
Example: #11335577  99  555555  555555 ••
Result: The lock is automatically set into B) Public Use Function and allows the programmed Technician Code to open the lock WITHOUT the entered single User Code being erased.
Note: If lock is opened with a Master Code the User Code will be erased.

 

 

 

POI-KL1000-v3:0515

 © 2019 Codelocks Ltd.  All rights reserved.
    • Related Articles

    • KL1000 Classic Programming and Operating Instructions [GB]

      Codes - The Basics • The KitLock has four code levels available: i) Master Code ii) Sub-Master Code iii) User Code iv) Technician Code • The KitLock is supplied with two factory set codes: Master Code: 11335577 User Code: 2244 • When fitted, ...
    • CL4500 - Programming and Operating Instructions

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. About CL4500 The CL4500 and ...
    • CL5500 - Programming and Operating Instructions

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support . About CL5500 The CL4500 and ...
    • KL1000 Classic Getting Started Guide [GB]

      The KL1000 Classic is supplied with a factory set Master Code (11335577) and User Code (2244), and the Private Use Function enabled.  In this function, the lock will remain locked until a valid 4 digit User Code is entered. On entry of a valid User ...
    • KL1000 Classic+ - Programming and Operating Instructions

      IMPORTANT: This guide is for the KL1000 Classic+ model. The standard KL1000 Classic Programming and Operating Instructions are available here. The KL1000 Classic+ is a compact digital lock based on the venerable KL1000 Classic, with the additional ...