A3 RFID - Getting Started Guide

A3 RFID - Getting Started Guide

ABOUT

The A3 RFID Standalone Door Controller is a compact, standalone programmable access control system that provides proximity access for up to 1000 users.

SPECIFICATIONS

Clients

Compatible With              13.56MHz MIFARE® (ISO14443 Type A)
Max. Capacity                  1000

Operation

Voltage                             12-24V DC
Idle Current                      20mA
Working Current              80mA
Max. Output Load            2A
Relay Output Time           1-99s (5s default)
Inputs/Outputs                 Relay, Push-to-Exit
Read Range                     60mm (23/8”)
Environment Rating         IP66
Temperature                    -30°C ~ 60°C (-22°F ~ 140°F)
Humidity                           10%RH ~ 98%RH


INSTALLATION

BOX CONTENTS

Description
Quantity
A3 RFID Standalone Door Controller
1
Remote Control Programmer
1
Master Programming Cards
     Master Add Card (1)
     Master Delete Card (1)
2
Allen Key
1
Self-Tapping Screws
2
Wall Plugs
2
1N4004 Diode
1


INSTALL

1. Remove back cover from the unit by removing the bottom screw.
2. To surface mount (1), drill two fixing holes (2) and a cable passage hole.
3. Fix back cover to the wall.
4. Thread cable through back cover into cable passage hole.
5. Reattach unit to the back cover.


(1) The unit may also be flush mounted.
(2) Use appropriate fixings for your application. Wall plugs supplied may not be suitable for all applications.

WIRING

Colour
Function
Notes
Red
Power+
12-24V DC Regulated Power Supply
Black
GND
Ground
White
NO
Normally Open Relay Output
Brown
COM
Common Connection for Relay Output
Green
NC
Normally Closed Relay Output
Yellow
OPEN
Request to Exit


WIRING DIAGRAMS


Note: Install a 1N4004 or equivalent diode when using a common power supply.
Note: Additional wiring diagrams are available www.codelocks.com


OPERATING INSTRUCTIONS

When first powered, the unit will require programming. The pre-registered Master Programming Cards can be used to quickly add (and delete) new clients. For further programming, use the infrared Remote Control Programmer provided.

GENERAL OPERATION

Unlock/Open Door
Present a valid Card Client to the unit
The LED will turn green and a single beep will sound to indicate acceptance
Silence Alarm
Present a valid Card Client, or enter the Master Code via the infrared Remote Control Programmer to silence the alarm
Exit Programming Mode
To exit Programming Mode at any time, press the * button until you see a solid red light


CHANGE THE MASTER CODE

Note: The Master Code is 6 digits in length. Factory set Master Code is 123456.

Enter Programming Mode
* Master Code #

Enter New Master Code
0 New Master Code # New Master Code #
Exit Programming Mode
*

ADD CARD CLIENTS

New Card Clients can be added via the infrared Remote Control Programmer or using the Master Add Card.

Enter Programming Mode
* Master Code #
Add a Card Client
Unit will assign the Card Client to the next available ID. Multiple Card Clients may be added sequentially
0 New Master Code # New Master Code #
OR

Add a Card Client to Specific ID
Card Client to the specified ID (1-1000)
(No zero padding required)
1 Specific Client ID # Present Card #
Exit Programming Mode
*

The Master Add Card can be used to add new Card Clients directly, without using the Remote Control Programmer. Using this method, the new Card Client will be assigned to the next available ID.

Add a Card Client via
Master Add Card
1. Present Master Add Card
2. Present new Card Client (repeat as required)
3. Present Master Add Card to end


DELETE CARD CLIENTS

Existing Card Clients can be deleted via the infrared Remote Control Programmer or using the Master Delete Card.

Enter Programming Mode
* Master Code #
Delete a Card Client
Presented Card Client will be deleted. Multiple Card Clients can be deleted sequentially.
2 Present Card #
OR

Add a Card Client to Specific ID
Unit will delete the Card Client at the specified ID (1-1000)
2 Specific Client ID # *
OR

Delete all Card Clients
2 0 0 0 0 #
Exit Programming Mode
*

The Master Delete Card can delete Card Clients directly. The Card Client to be deleted must be present.

Delete a Card Client
via Master Delete Card
1. Present Master Delete Card
2. Present new Card Client (repeat as required)
3. Present Master Delete Card to end



RELAY CONFIGURATION

Pulse Mode is enabled by default, with a re-lock time of 5 seconds.

Enter Programming Mode
* Master Code #
Pulse Mode
Adjustable re-lock time can be set between 1-99s (Default 5s)
4 <1-99> #
OR

Latch Mode
Enables passage function

40 #
Exit Programming Mode
*



PENALTY TIME

Presenting an incorrect Card Client 10 times will incur a 30 second time delay before any further use is possible.

Enter Programming Mode
* Master Code #
Disable Penalty
Penalty is disabled by default
7 0 #
OR

Enable Penalty
(30s, no alarm)
7 1 #
OR

Enable Penalty
(30s, with alarm)
Note: A valid Card Client will silence the alarm and a second valid Card Client will allow access.
7 2 #
Exit Programming Mode
*



RESET

Reset & Reassign Master Programming Cards 

Note: You will require two compatible cards to assign the Master Add Card and Master Delete Card
Note: Does not clear Card Clients (See Delete Card Clients for details on how to remove Card Clients)
1. Disconnect power source
2. Press and hold push-to-exit button
3. Reconnect power source (two beeps and LED turns yellow)
4. Release push-to-exit button
5. Present each card in turn;
a) First card presented will become the Master Add Card
b) Second card presented will become the Master Delete Card
6. LED will burn red to indicate end of reset process


INDICATIONS

Description
LED
Sounder
Standby
Red, continuous
No sound
Enter Programming Mode
Red, flashing
Single beep
Programming Mode Active
Light green, continuous
Single beep
Operation Error
None
Three beeps
Exit Programming
Mode
Red, continuous
Single beep
Access Granted
Bright green
Single beep
Alarm
Red, rapid flashing
Alarm


MIFARE® is a registered trademark of NXP B.V. and is used under license.



GSG-AL03RM-v1-0819

© 2019 Codelocks Ltd.  All rights reserved.

    • Related Articles

    • KL1100 RFID - Getting Started Guide

      ABOUT KL1100 RFID The KL1100 RFID can operate in Standalone Mode or in Remote Card Authorisation (RCA) Mode. RCA Mode gives the ability to remotely set-up and allocate cards to locks or lock groups with our offline or cloud based software. This ...
    • CL5510 - Getting Started Guide

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. About Codelocks Smart Locks ...
    • CL4500 - Getting Started Guide

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. About Codelocks Smart Locks ...
    • A3 RFID - Installation Template

      Important! When printing templates, check your print settings to make sure that the template is printed at 100% of the actual size. Once printed, check the measurements on the template with a ruler before drilling your door or cabinet.   Open ...
    • C3 Smart User Guide

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. Download C3 Smart 1. Search ...