Description | Quantity |
A3 RFID Standalone Door Controller | 1 |
Remote Control Programmer | 1 |
Master Programming Cards Master Add Card (1) Master Delete Card (1) | 2 |
Allen Key | 1 |
Self-Tapping Screws | 2 |
Wall Plugs | 2 |
1N4004 Diode | 1 |

| Colour | Function | Notes |
Red | Power+ | 12-24V DC Regulated Power Supply |
Black | GND | Ground |
White | NO | Normally Open Relay Output |
Brown | COM | Common Connection for Relay Output |
Green | NC | Normally Closed Relay Output |
Yellow | OPEN | Request to Exit |

Unlock/Open Door | Present a valid Card Client to the unit The LED will turn green and a single beep will sound to indicate acceptance |
Silence Alarm | Present a valid Card Client, or enter the Master Code via the infrared Remote Control Programmer to silence the alarm |
Exit Programming Mode | To exit Programming Mode at any time, press the * button until you see a solid red light |
| Enter Programming Mode | * Master Code # |
| Enter New Master Code | 0 New Master Code # New Master Code # |
| Exit Programming Mode | * |
| Enter Programming Mode | * Master Code # |
| Add a Card Client Unit will assign the Card Client to the next available ID. Multiple Card Clients may be added sequentially | 0 New Master Code # New Master Code # |
OR | |
Add a Card Client to Specific ID Card Client to the specified ID (1-1000) (No zero padding required) | 1 Specific Client ID # Present Card # |
| Exit Programming Mode | * |
Add a Card Client via Master Add Card | 1. Present Master Add Card 2. Present new Card Client (repeat as required) 3. Present Master Add Card to end |
| Enter Programming Mode | * Master Code # |
| Delete a Card Client Presented Card Client will be deleted. Multiple Card Clients can be deleted sequentially. | 2 Present Card # |
| OR | |
Add a Card Client to Specific ID Unit will delete the Card Client at the specified ID (1-1000) | 2 Specific Client ID # * |
OR | |
Delete all Card Clients | 2 0 0 0 0 # |
Exit Programming Mode | * |
Delete a Card Client via Master Delete Card | 1. Present Master Delete Card 2. Present new Card Client (repeat as required) 3. Present Master Delete Card to end |
| Enter Programming Mode | * Master Code # |
Pulse Mode Adjustable re-lock time can be set between 1-99s (Default 5s) | 4 <1-99> # |
| OR | |
Latch Mode Enables passage function | 40 # |
| Exit Programming Mode | * |
| Enter Programming Mode | * Master Code # |
Disable Penalty Penalty is disabled by default | 7 0 # |
| OR | |
Enable Penalty (30s, no alarm) | 7 1 # |
| OR | |
| Enable Penalty (30s, with alarm) Note: A valid Card Client will silence the alarm and a second valid Card Client will allow access. | 7 2 # |
| Exit Programming Mode | * |
Reset & Reassign Master Programming Cards Note: You will require two compatible cards to assign the Master Add Card and Master Delete Card Note: Does not clear Card Clients (See Delete Card Clients for details on how to remove Card Clients) | 1. Disconnect power source 2. Press and hold push-to-exit button 3. Reconnect power source (two beeps and LED turns yellow) 4. Release push-to-exit button 5. Present each card in turn; a) First card presented will become the Master Add Card b) Second card presented will become the Master Delete Card 6. LED will burn red to indicate end of reset process |
Description | LED | Sounder |
Standby | Red, continuous | No sound |
Enter Programming Mode | Red, flashing | Single beep |
Programming Mode Active | Light green, continuous | Single beep |
Operation Error | None | Three beeps |
Exit Programming Mode | Red, continuous | Single beep |
Access Granted | Bright green | Single beep |
Alarm | Red, rapid flashing | Alarm |
© 2019 Codelocks Ltd. All rights reserved.