A3 DUAL - Getting Started Guide

A3 DUAL - Getting Started Guide

ABOUT

The A3 Dual Standalone Keypad Door Controller with RFID is a compact, standalone programmable access control system that provides proximity access for up to 600 users.

SPECIFICATIONS

ADV   Advanced Features
Guides, programming instructions and wiring diagrams for the A3 Dual advanced features can be found at: www.codelockssupport.com

Clients

Compatible With              13.56MHz MIFARE® (ISO14443 Type A) & 125KHz
Max. Capacity                  598 Standard Clients: (Code and/or Card)
                                          2 Panic Clients

Operation

Voltage                             12-18V DC
Idle Current                      35mA
Working Current              100mA
Max. Output Load            2A
Relay Output Time           1-99s (5s default)
Inputs/Outputs                 Relay, Push-to-Exit, Alarm, Door Contact, Wiegand Input, Wiegand Output
Weiguard ADV                 Input/Output: 26-37 bits
                                           PIN Output: 4 bits, 8 bits (ASCII), 10 Digits Virtual Number (4 bits default)
Read Range                     60mm (2 3/8”)
Environment Rating         IP66
Temperature                    -40°C ~ 60°C (-40°F ~ 140°F)
Humidity                           0%RH ~ 98%RH


INSTALLATION

BOX CONTENTS

Description
Quantity
A3 RFID Standalone Door Controller
1
Master Programming Cards
     Master Add Card (1)
     Master Delete Card (1)
2
Allen Key
1
Self-Tapping Screws
2
Wall Plugs
2
1N4004 Diode
1


INSTALL

1. Remove back cover from the unit by removing the bottom screw
2. Drill two fixing holes (1) and a cable passage hole
3. Fix back cover to the wall
4. Thread cable through back cover into cable passage hole
5. Reattach unit to the back cover



(1) Use appropriate fixings for your application. Wall plugs supplied may not be suitable for all applications.

WIRING

Standalone 

Colour
Function
Notes
Red
Power+
12-18V DC Regulated Power Supply
Black
GND
Ground
Blue
NO
Normally Open Relay Output
Purple
COM
Common Connection for Relay Output
Orange
NC
Normally Closed Relay Output
Yellow
OPEN
Request to Exit

Wiegand Wiring (Wiegand Reader or Controller) ADV

Colour
Function
Notes
Green
D0
Wiegand Input/Output Data 0
White
D1
Wiegand Input/Output Data 1


Advanced I/O Features) ADV

Colour
Function
Notes
Grey
Alarm Output
Negative Contact for Alarm
Brown
Door Contact
Door Contact Input (NC)


WIRING DIAGRAMS


Note: Install a 1N4004 or equivalent diode when using a common power supply.


OPERATING INSTRUCTIONS

When first powered, the unit will be in Standalone/Controller Mode; the unit acts as both controller and reader, and will allow both Card Clients and Code Clients to be programmed. The pre-registered Master Programming Cards can be used to quickly add (and delete) new Card Clients. For further programming, the keypad can be used.

ADV Additional access modes are available.

GENERAL OPERATION

Unlock/Open Door
Present a valid Card Client to the unit or enter a valid Code Client followed by a #
Example: 5 7 4 2 #
The LED will turn green and a single beep will sound to indicate acceptance
Silence Alarm
Present a valid Code or Card Client, or enter the Master Code to silence the alarm
Exit Programming Mode
To exit Programming Mode at any time, press the * button until you see a solid red light


CHANGE THE MASTER CODE

Note: The Master Code is 6 digits in length. Factory set Master Code is 123456.

Enter Programming Mode

Master Code #

Enter New Master Code
0 New Master Code # New Master Code #
Exit Programming Mode
*


ADD CARD CLIENTS

New Card Clients can be added via the infrared Remote Control Programmer or using the Master Add Card.

Enter Programming Mode
* Master Code #
Add a Card Client
Unit will assign the Card Client to the next available ID. 
1 Present Card

Multiple Card Clients may be added by presenting them consecutively before exiting Programming Mode
OR

Add a Card Client to Specific ID
Unit will assign the Card Client to the specified ID (1-598)

1 Specific Client ID # Present Card #
Exit Programming Mode
*

The Master Add Card can be used to add new Card Clients directly, without using the keypad. Using this method, the new Card Client will be assigned to the next available ID.

Add a Card Client via
Master Add Card
1. Present Master Add Card
2. Present new Card Client (repeat as required)
3. Present Master Add Card to end


ADD CODE CLIENTS

New Code Clients can be added via the keypad.

Note: Code Clients may be 4-6 digits long. The code 8 8 8 8 is reserved and cannot be used.

Enter Programming Mode
* Master Code #
Add a Code Client

The Code Client will be assigned to the next available ID. Multiple Code Clients may be added sequentially.
Single Client
1 Enter New Code #

Multiple Code Clients
1 Enter New Code # Enter New Code # Enter New Code # (repeat as required)
OR

Add a Card Client to Specific ID
Unit will assign the Code Client to the specified ID (1-598).

Specific Client ID (1 - 598) # Enter New Code #
Exit Programming Mode
*


ADD PANIC CLIENTS

A Panic Client allows access and will trigger an alarm if connected.

Enter Programming Mode
* Master Code #
Add a Panic Card
The Code Client will be assigned to the next available ID. Multiple Code Clients may be added sequentially.
1 Client ID (599 or 600) # Present Card
OR

Add a Panic Code

1 Client ID (599 or 600) # Enter New Code #
Exit Programming Mode
*


DELETE CARD CLIENTS

Existing Card Clients can be deleted via the infrared Remote Control Programmer or using the Master Delete Card.

Enter Programming Mode
* Master Code #
Delete a Card Client
Presented Card Client will be deleted. Multiple Card Clients can be deleted sequentially.

Single Client
2
Present Card #

Multiple Clients
2
 Present Card - Present Card - Present Card (repeat as required) #

OR

Add a Card Client to Specific ID
Unit will delete the Card Client at the specified ID (1-598)
2 Specific Client ID #
OR

Delete all Clients
2 Master code #
Exit Programming Mode
*

The Master Delete Card can delete Card Clients directly. The Card Client to be deleted must be present.

Delete a Card Client
via Master Delete Card
1. Present Master Delete Card
2. Present new Card Client (repeat as required)
3. Present Master Delete Card to end


DELETE CODE CLIENTS

Existing Card Clients can be deleted via the infrared Remote Control Programmer or using the Master Delete Card.

Enter Programming Mode
Master Code #
Delete a Code Client
Code Client entered will be deleted. Multiple Code Clients may be deleted sequentially.

Single Client
2
 Enter Code #

Multiple Clients
2
 Enter Code - Enter Code - Enter Code # (repeat as required)

OR

Delete a Code Client by Specific ID
Unit will delete the Code Client at the specified ID
2 Specific Client ID #
OR

Delete all Clients
Unit will delete all Card
and Code Clients.
Master Code #
Exit Programming Mode
*



CHANGE A USER'S CODE

This can be done when the unit is not in programming mode.

Change Code by Specific Client ID
* Specific Client ID (1-598) # Enter Old Code # Enter New Code # Repeat New Code # *


RELAY CONFIGURATION

Pulse Mode is enabled by default, with a re-lock time of 5 seconds.

Enter Programming Mode
* Master Code #
Pulse Mode
Adjustable re-lock time can be set between 1-99s (Default 5s)
3 <1-99> #
OR

Latch Mode
Enables passage function
3 0 #
Exit Programming Mode
*



DOOR DETECTION

Door detection is disabled by default. When enabled and a door contact is fitted, an alarm will sound if the door is left open for one or more minutes. Should the door be forced open, or if the door has not closed properly, the alarm will sound. The alarm will automatically silence after one minute or a valid Code or Card Client is presented.

Enter Programming Mode
* Master Code #
Disable Door Detection (Default)
5 0 #
OR

Enable Door Detection
5 1 #
Exit Programming Mode
*


PENALTY TIME

Presenting an incorrect Card Client 10 times will incur a 30 second time delay before any further use is possible.

Enter Programming Mode
* Master Code #
Disable Penalty
Penalty is disabled by default
6 0 #
OR

Enable Penalty
(30s, no alarm)
6 1 #
OR

Enable Penalty
(30s, with alarm)
Note: A valid Card Client will silence the alarm.
6 2 #
Exit Programming Mode
*



VISUAL/AUDIBLE FEEDBACK


Enter Programming Mode
* Master Code #
Sounder

Disable
7 0 #
Enable (Default)
7 1 #
LED

Disable
7 2 #
Enable
7 3 #
Exit Programming Mode
*


RESET

Reset & Reassign Master Programming Cards 

Note: You will require two compatible cards to assign the Master Add Card and Master Delete Card
Note: Does not clear Card Clients (See Delete Card Clients for details on how to remove Card Clients)
1. Disconnect power source
2. Press and hold push-to-exit button
3. Reconnect power source (two beeps and LED turns yellow)
4. Release push-to-exit button
5. Present each card in turn;
a) First card presented will become the Master Add Card
b) Second card presented will become the Master Delete Card
6. LED will burn red to indicate end of reset process


INDICATIONS

Description
LED
Sounder
Standby
Red, continuous
No sound
Enter Programming Mode
Red, flashing
Single beep
Programming Mode Active
Light green, continuous
Single beep
Operation Error
None
Three beeps
Exit Programming
Mode
Red, continuous
Single beep
Access Granted
Bright green
Single beep
Alarm
Red, rapid flashing
Alarm


WIRING DIAGRAMS


Note: Install a 1N4004 or equivalent diode when using a common power supply.



MIFARE® is a registered trademark of NXP B.V. and is used under license.

GSG-AL03DX-v1-0819

© 2019 Codelocks Ltd.  All rights reserved.

    • Related Articles

    • KL1100 RFID - Getting Started Guide

      ABOUT KL1100 RFID The KL1100 RFID can operate in Standalone Mode or in Remote Card Authorisation (RCA) Mode. RCA Mode gives the ability to remotely set-up and allocate cards to locks or lock groups with our offline or cloud based software. This ...
    • CL5510 - Getting Started Guide

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. About Codelocks Smart Locks ...
    • CL4500 - Getting Started Guide

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. About Codelocks Smart Locks ...
    • C3 Smart User Guide

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. Download C3 Smart 1. Search ...
    • C3 Smart User Guide

      Notice: The C3 Smart App replaced the K3 Connect App on February 14, 2023. For more information on how to download, set up and use C3 Smart with your Codelocks Smart Locks, visit: c3smart.net or contact Codelocks Support. Download C3 Smart 1. Search ...