Description | Quantity |
A3 RFID Standalone Door Controller | 1 |
Master Programming Cards Master Add Card (1) Master Delete Card (1) | 2 |
Allen Key | 1 |
Self-Tapping Screws | 2 |
Wall Plugs | 2 |
1N4004 Diode | 1 |
Colour | Function | Notes |
Red | Power+ | 12-18V DC Regulated Power Supply |
Black | GND | Ground |
Blue | NO | Normally Open Relay Output |
Purple | COM | Common Connection for Relay Output |
Orange | NC | Normally Closed Relay Output |
Yellow | OPEN | Request to Exit |
Colour | Function | Notes |
Green | D0 | Wiegand Input/Output Data 0 |
White | D1 | Wiegand Input/Output Data 1 |
Colour | Function | Notes |
Grey | Alarm Output | Negative Contact for Alarm |
Brown | Door Contact | Door Contact Input (NC) |
Unlock/Open Door | Present a valid Card Client to the unit or enter a valid Code Client followed by a # Example: 5 7 4 2 # The LED will turn green and a single beep will sound to indicate acceptance |
Silence Alarm | Present a valid Code or Card Client, or enter the Master Code to silence the alarm |
Exit Programming Mode | To exit Programming Mode at any time, press the * button until you see a solid red light |
Enter Programming Mode | * Master Code # |
Enter New Master Code | 0 New Master Code # New Master Code # |
Exit Programming Mode | * |
Enter Programming Mode | * Master Code # |
Add a Card Client Unit will assign the Card Client to the next available ID. | 1 Present Card Multiple Card Clients may be added by presenting them consecutively before exiting Programming Mode |
OR | |
Add a Card Client to Specific ID Unit will assign the Card Client to the specified ID (1-598) | 1 Specific Client ID # Present Card # |
Exit Programming Mode | * |
Add a Card Client via Master Add Card | 1. Present Master Add Card 2. Present new Card Client (repeat as required) 3. Present Master Add Card to end |
Enter Programming Mode | * Master Code # |
Add a Code Client | Single Client 1 Enter New Code #Multiple Code Clients 1 Enter New Code # Enter New Code # Enter New Code # (repeat as required) |
OR | |
Add a Card Client to Specific ID Unit will assign the Code Client to the specified ID (1-598). | 1 Specific Client ID (1 - 598) # Enter New Code # |
Exit Programming Mode | * |
Enter Programming Mode | * Master Code # |
Add a Panic Card The Code Client will be assigned to the next available ID. Multiple Code Clients may be added sequentially. | 1 Client ID (599 or 600) # Present Card |
OR | |
Add a Panic Code | 1 Client ID (599 or 600) # Enter New Code # |
Exit Programming Mode | * |
Enter Programming Mode | * Master Code # |
Delete a Card Client Presented Card Client will be deleted. Multiple Card Clients can be deleted sequentially. | Single Client 2 Present Card #Multiple Clients 2 Present Card - Present Card - Present Card (repeat as required) # |
OR | |
Add a Card Client to Specific ID Unit will delete the Card Client at the specified ID (1-598) | 2 Specific Client ID # |
OR | |
Delete all Clients | 2 Master code # |
Exit Programming Mode | * |
Delete a Card Client via Master Delete Card | 1. Present Master Delete Card 2. Present new Card Client (repeat as required) 3. Present Master Delete Card to end |
Enter Programming Mode | * Master Code # |
Delete a Code Client Code Client entered will be deleted. Multiple Code Clients may be deleted sequentially. | Single Client 2 Enter Code #Multiple Clients 2 Enter Code - Enter Code - Enter Code # (repeat as required) |
OR | |
Delete a Code Client by Specific ID Unit will delete the Code Client at the specified ID | 2 Specific Client ID # |
OR | |
Delete all Clients Unit will delete all Card and Code Clients. | 2 Master Code # |
Exit Programming Mode | * |
Change Code by Specific Client ID | * Specific Client ID (1-598) # Enter Old Code # Enter New Code # Repeat New Code # * |
Enter Programming Mode | * Master Code # |
Pulse Mode Adjustable re-lock time can be set between 1-99s (Default 5s) | 3 <1-99> # |
OR | |
Latch Mode Enables passage function | 3 0 # |
Exit Programming Mode | * |
Enter Programming Mode | * Master Code # |
Disable Door Detection (Default) | 5 0 # |
OR | |
Enable Door Detection | 5 1 # |
Exit Programming Mode | * |
Enter Programming Mode | * Master Code # |
Disable Penalty Penalty is disabled by default | 6 0 # |
OR | |
Enable Penalty (30s, no alarm) | 6 1 # |
OR | |
Enable Penalty (30s, with alarm) Note: A valid Card Client will silence the alarm. | 6 2 # |
Exit Programming Mode | * |
Enter Programming Mode | * Master Code # |
Sounder | |
Disable | 7 0 # |
Enable (Default) | 7 1 # |
LED | |
Disable | 7 2 # |
Enable | 7 3 # |
Exit Programming Mode | * |
Reset & Reassign Master Programming Cards Note: You will require two compatible cards to assign the Master Add Card and Master Delete Card Note: Does not clear Card Clients (See Delete Card Clients for details on how to remove Card Clients) | 1. Disconnect power source 2. Press and hold push-to-exit button 3. Reconnect power source (two beeps and LED turns yellow) 4. Release push-to-exit button 5. Present each card in turn; a) First card presented will become the Master Add Card b) Second card presented will become the Master Delete Card 6. LED will burn red to indicate end of reset process |
Description | LED | Sounder |
Standby | Red, continuous | No sound |
Enter Programming Mode | Red, flashing | Single beep |
Programming Mode Active | Light green, continuous | Single beep |
Operation Error | None | Three beeps |
Exit Programming Mode | Red, continuous | Single beep |
Access Granted | Bright green | Single beep |
Alarm | Red, rapid flashing | Alarm |
© 2019 Codelocks Ltd. All rights reserved.